Termoelektrarna Toplarna Ljubljana


Extraction Condensing (Back-Pressure) Agregate
Boilers:
ManufacturerGanzDjuro Djakovic
Capacity2 x 40/50 kg/s 75 kg/s
2 x 1 45/180 t/h 720 t/h
Fresh steam pressure94 bar94 bar
Steam temperature 535 oC 535 oC
Year of construction19661984

valign=top
Turbines:
Manufacturer Jugoturbina Jugoturbina
Nominal capacity 2 x 32 MW 50 MW
Steam pressure 90 bar 90 bar
Steam temperature 535 oC 535 oC
Technologic steam pressure 8.5 bar 8.5 bar
Heating steam pressure 2.5 bar 1.4 bar
Year of construction 19661984

Peak Load Heating Station (LPB - low pressure boiler station)
Boilers: Hot Water Steam
Manufacturer- type TPK - VKLM TPK BKG - 200
Nominal capacity 2 x 58 MW2 x 5.6 kg/s (20 Vh)
Water flow 2 x 0.28 m3/s
Temperature of water-steam 130/195 oC 280 oC
Steam differential pressure 20 bar 10 bar
Year of construction 19791985

Heating Stations and Water Pump Station
Thermal power 116 MW 116 MW and 2 x 60 MW
Network water flow 0.78m3/s 1.11 m3/s and 0.56m3/s
Pre-flow pressure 10.0 bar 10.0 bar
Return pressure 1.5 bar 1.5 bar
Technological steam 13.5 kg/s (50 Vh)13.5 kg/s (50 Vh)
Year of construction 19661984 and 1979,1985


Toplarna Siska